Basic Info.
Model NO. | AGn16 | Power Source | USB Type-C |
Trademark | OEM/ODM | Origin | Kunshan,China |
Sensor Type | NDIR | HS Code | 9027100090 |
CO2 Range | 0~5000ppm | Production Capacity | 80000 Pieces/Year |
Temperature Range | 0~50ºC(32°F to 122°F) | Transport Package | Carton |
RH Range | 0-100% | Package Type | 1 pcs/Color Box |
Battery | Internal 1000mA | Weight | 103g Device only |
Single Package Size | 120*66*33mm (4.7*2.6*1.3inch) |
|
|
Product Description:
With built_in NDIR technology to improve long term stability, AGn16 is a smart desktop mini CO2 monitor, designed to accurately track air quality within CO2, temperature and humidity. The portable CO2 detector size of a palm is easy to carry and can detect the air quality in schools, office buildings, hotels, hospitals, laboratories, greenhouse andanywhere that high levels of carbon dioxide are generated. With an internal recharge LI battery, AGn16 can keep work 48 hours without external power supply.
Feature:
Ø NDIR (Non-Dispersive-Infrared) technology is used to improve the long term stability
Ø CO2/Temperature/RH Monitor; Tracer
Ø CO2 concentration indicator
Ø Build-In recharge LI battery
Ø 3-color indicator bar (green / yellow / red) gradually changes with CO2 concentration
Ø Adjustable three-stage backlight function
Ø Only one key, easy for use.
Operating Instructions
Initial Setup: When first unboxing, plug in the unit to the included Type-C USB (or one of your own to almost any cellphone charger or USB power source). Then LED display shows a countdown from 15seconds for warm up .Once the countdown is complete, your product is ready to use.
Specifications:
Typical test conditions, unless otherwise specified: Ambient Temp =23+/-3°C, RH=50%-70%, Altitude=0~100 meter
Measurement | Specification |
Operating Temperature | 32°F to 122°F (0°C to 50°C) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
Operating & Storage RH | 0-95%, non-condensing |
CO2 Measurement |
|
Accuracy at 0~3000ppm | ±50ppm or ±5% of reading, whichever is greater |
Accuracy over 3000ppm | ±7% |
Repeatability | 20ppm at 400ppm (standard dev. of 10 readings in 1 minute) |
Measurement Range | 0-5000ppm |
Display Resolution | 1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000) |
Temp Dependence | ±0.1% of reading per °C or ±2ppm per °C, whichever is greater, referenced to 25°C |
Pressure Dependence | 0.13% of reading per mmHg (corrected by user's altitude input) |
Response Time | <2min for 63% of step change or <4.6min for 90% step change |
Warm-up Time | <30 sec |
Temp Measurement |
|
Operating Temperature | 32°F to 122°F (0°C -50°C) |
Display Resolution | 0.2°F (0.1°C) |
Accuracy | ±1°F (±0.5°C) |
Response Time | <20min (63%) |
RH Measurement |
|
Range | 0-100% |
Accuracy | ±5% |
Resolution | 1% on Main Reading, 0.1% on Max Min Reading |
|
|
Power Requirements | 160mA Peak, 15mA average at 5.0V |
Battery Life | 1000mA Recharge LI Battery 48 hours (Test by factory laboratory) |
Dimension | 120*91.2*27mm (4.7*3.6*1.1inch) |
Weight | 148g ( 5.22oz) Device only, AC Adapter not included |