Basic Info.
Model NO. | AGc11 | Buzzer Sound | 70dB @10cm |
Trademark | OEM/ODM | Power Source | AC 100 ~ 240 VAC |
Sensor Type | Dual-Beam NDIR | Origin | Kunshan,China |
CO2 Range | 0~5000ppm | HS Code | 9027100090 |
Display Type | LCD | Production Capacity | 80000 Pieces/Year |
Photo Cell | Auto detect Day/Night | Transport Package | Carton |
Sensor Unit Size | 153*33*27mm (6.0*1.3*1.1inch) | Package Type | 1 pcs/Color Box |
Output | Piggyback 110~250VAC | Weight | 700g ( 24.7oz) |
Product Description:
AGc11 CO2 controller, a CO2 monitor and controller with Integrated Sensor, has both audible and visual alarms for Greenhouse mode and Vent mode.
By using built-in Dual Beam NDIR technology and Day/Night auto detect sensor, it could control the other connected devices,such as CO2 generator to help increase plant yields by supplying CO2 requiredfor photosynthesis.
It is perfect used in agricultural applications like greenhouse/ hydroponics rooms, plant factories.
Feature:
Ø Dual Beam NDIR(Non-Dispersive-Infrared) technology is used to improve the long term stability.
Ø CO2 controller; Tracer
Ø Built-in Day/Night detect sensor
Ø Chart with variable time Zoom Levels
Ø Foolproof “Hold Home” function
Ø Good Zone display indicate
Ø Green backlight
Auto Detect Day/Night
The built-in Photo-Cell sensor can automatically detect whether it is Day or Night.
In Greenhouse (Increase) mode it can override the CO2 control and shut off the CO2 generator by turning off the output power (CO2 Equipment socket)during the night. Conversely, if the Photo-Cell detects light and the CO2 level is low, the device will start the CO2 generator by turning on the output power (CO2 Equipment socket).
In Vent(Decrease) mode, Photo-Cell status does not affect the output power (Exhaust Fan socket) ON or OFF.
Greenhouse (INCREASE) Control
This CO2 controller can be set for Green House mode application by S5 ADVANCE Mode setting, CO2 Equipment socket is on when CO2 concentration is below Set Target Low, and off when CO2 concentration is over Set Target Hi. For example, if the Set Target Low is 1000ppm,and the Set Target Hi is 1400ppm, the output power will shut off when CO2over 1400ppm, and power on when CO2below 1000ppm.
Vent (DECREASE) Mode Control
This CO2 controller can be set for Vent mode application by S5 ADVANCE Mode setting. Exhaust Fan socket is on when CO2 concentration is over Set Target Hi, and off when CO2 concentration is below Set TargetLow
Specifications:
Typical test conditions, unless otherwise specified: Ambient Temp =23+/-3°C, RH=50%-70%, Altitude=0~100 meter
Measurement | Specification |
Operating Temperature | 32°F to 104°F (0°C to 40°C) |
Storage Temperature | -4°F to 140°F (-20°C to 60°C) |
Designed For | Indoor use |
Operating & Storage RH | 0-95%, non-condensing |
CO2 Measurement |
|
Accuracy at 0~3000ppm | ±50ppm or ±5% of reading, whichever is greater |
Accuracy over 3000ppm | ±7% |
Repeatability | 20ppm at 400ppm (standard dev. of 10 readings in 1 minute) |
Measurement Range | 0-5000ppm |
Display Resolution | 1ppm (0-1000); 5ppm (1000-2000); 10ppm (>2000) |
Temp Dependence | ±0.2% of reading per °C or ±2ppm per °C, whichever is greater, referenced to 25°C |
Pressure Dependence | 0.13% of reading per mmHg (corrected by user’s altitude input) |
Response Time | <2min for 63% of step change or <4.6min for 90% step change |
Warm-up Time | <30 sec |
Power Input/Output | AC 120VAC, 60Hz, Current: 10A Max |
Mains Supply Voltage | Fluctuations up to ±10% of the nominal voltage |
Applicable Pollution | Degree of the intended environment (POLLUTION DEGREE 2) |
Dimension | Socket Unit: 115*45*38 mm (4.5*1.8*1.5inch) Control Unit: 195*145*44mm (7.7*5.7*1.7inch) |
Weight | 760g ( 26.8oz) |